  • Time Electronics 1006 DC MiliVolt Source Time Electronics 1006 DC MiliVolt Source

1006 DC MilliVolt Source

Quick Overview

A high accuracy handheld millivolt source primarily used for voltage injection, with 3 from 1µV to 1V and 0.02% accuracy. Applications include thermocouple simulation and calibration of A/D converters and chart recorders.

Download Data Sheet | Manual

Availability: In stock

$1,350.00
$1,350.00

Details

Features
  • 3 ranges up to 1V
  • Accuracy 0.02% of setting + 0.02% of range
  • 20mA output current
  • Powered by 6 x AA batteries
  • Best resolution 1µV
  • Safety terminals
  • 100 hours typical battery life
  • Short circuit and overload protected
  • Optional carry case
  • H8.4 x W3.9 x D4.7”, weight 2.5 lbs
The 1006 is an accurate low cost millivolt source suitable for voltage injection applications. Three output ranges are provided to give adjustable output values from 1µV to 1V with a basic 0.02% accuracy. For signal injection, the operator needs to switch on, check the battery condition, select the range, and set the required voltage using the thumbwheel switches. The 1006 uses a precision reference diode and low temperature coefficient resistors to give a highly stable output. Power is provided by 6 AA batteries. Battery life is several months, depending on usage. The battery condition is monitored by an indicator mounted on the top of the unit. The 1006 has up to 20mA drive current and is short circuit and overload protected. An off/normal/reverse output polarity switch is provided. Safety Terminals Fitted as standard and fully compatible with 4mm shrouded plugs, as well as standard plugs, bare wires, and spade terminals. Added Protection The 1006 comes fitted with an ergonomic rubber cover providing increased protection and durability. It has a textured grip for comfortable handling and openings at the top and bottom to allow access to the battery meter and a position to place labels if required. It is easy to remove if the user prefers a stand-alone unit or to house the 1006 in the 9027 carry case. Applications As an accurate millivolt source, the 1006 can be used for many applications including thermocouple simulation (using appropriate lookup table), chart recorder calibration, A/D converter and DMM calibration, and as a stable voltage for backing off DC offsets. The 1006 is an easy to use calibration instrument designed for accuracy and reliability. As part of the Time Electronics portable test equipment range it is ideal for use in the lab or field.
  1. Real Quality Equipment review by Donnie Newman - Mississippi Power Co. on 2/9/2016
    Price
    Value
    Quality

    The TIME 1006 delivered as promised. Real quality equipment.

  2. Pleased review by Tom Talbot - NIMH - Bethesda, MD on 4/7/2014
    Price
    Value
    Quality

    Very pleased with the EHI customer service and the 1006. Would definitely order another one from them if needed.

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality