  1. Fluke 179 True RMS Multimeter

    The Fluke 179 True RMS multimeter features a 6000 count digital display that updates 4 x second. Data can also be displayed in analog bargraph format which includes 33 segments and updates 40 x second. Temperature range: -20 to 100°C True RMS AC voltage 0.1 mV to 1000V (1 kHz) DC voltage 0.1 mV to 1000V 0.1Ω to 50.00 MΩ resistance True RMS AC Current 0.01 mA to 10.00 A DC Current 0.01 mA to 10.00A

    Download Data Sheet | Manual
  2. Fluke 50 Series II Contact Thermometers

    Fluke 54, 53 52, 51, Dual/single input digital thermometers that feature laboratory accuracy (0.05% + 0.3°C) Temperature range: -20 to 100°C Accuracy (J, K, T, E, and N-type) Above -100°C: ±[0.05% + 0.3°C] | Below -100°C: ±[0.20% + 0.3°C] Display resolution: 0.1°C / F° / K < 1000° | 1°C/ °F / K >=1000° Single / Dual inputs (model dependent) Operating temperature: -10 to 50°C (14 to 122°F) Storage temperature: -40 to 60°C (-40 to 140°F)

    Download Overview | Manual
  3. Fluke 336A Series Clamp Meters

    Full featured clamp meters for use in tight spaces Large display Rugged and reliable Backlight (models 334, 335, 336) True RMS measurements (models 335, 336)

    Download Data Sheet | Manual
  4. Fluke 373 True RMS AC Clamp Meter

    Clamp meter that reads up to 600A AC and 600V AC or DC - replacing the Fluke 333A Diameter of Measurable Conductor: 1.26” or 32 mm max Operating Temperature: -14 to 122°F (-10 to 50°C) Operating Humidity: < 90% @ 10 to 30°C; < 75% @ 30 to 40°C Temperature Coefficient: 0.01%°C (<18°C or > 28°C) Reads up to 600A AC and 600V AC or DC Resistance measurement up to 6000Ω CAT IV 300V and CAT III 600V safety ratings

    Download Manual
  5. Fluke 374 True RMS AC/DC Clamp Meter

    Compatible with Fluke's iFlex flexible current probe which expands the measurement range to 2500A AC. Model 334A has been discontinued. The Fluke 374 is an appropriate replacement. Diameter of Measurable Conductor: 1.3” or 34 mm max Operating Temperature: -14 to 122°F (-10 to 50°C) Operating Humidity: < 90% @ 10 to 30°C; < 75% @ 30 to 40°C Temperature Coefficient: 0.01%°C (<18°C or > 28°C) CAT IV 600V and CAT III 1000V safety ratings

    Download Manual
  6. 1006 DC MilliVolt Source

    A high accuracy handheld millivolt source primarily used for voltage injection, with 3 from 1µV to 1V and 0.02% accuracy. Applications include thermocouple simulation and calibration of A/D converters and chart recorders.

    Download Data Sheet | Manual
  7. 1007 DC MilliVolt Potentiometer & Calibrator

    The 1007 is a handheld calibrator that can be used for potentiometric voltage measurement in addition to its operation as a millivolt source, with 3 ranges from 1µV to 1V and 0.02% accuracy.

    Download Data Sheet | Manual
  8. 1010 DC Voltage Calibrator

    A highly stable and accurate mains/battery powered calibrator for applications requiring a precision voltage source of low internal resistance. It has five ranges up to 10V with a resolution up to 0.01μV.

    Download Data Sheet | Manual
  9. 1017 Voltage/Current/Resistance Calibrator

    A portable multifunction calibrator with voltage, current, and resistance ranges. The 1017 is suitable for calibrating a wide range of instruments including thermocouples, transducers, transmitters, and platinum resistance thermometers.

    Download Data Sheet | Manual
  10. 1021 DC Current Source

    A precision portable DC current source suitable for calibration and test applications from micro-amp levels up to 100mA. The 1021 is used to calibrate current sensitive transducers and their associated indicating and recording instruments.

    Download Data Sheet | Manual