Quick Overview

The Fluke 725 Multifunction Process Calibrator is a powerful, yet easy-to-use field calibrator. Use the measure and source functions to test and calibrate almost any process parameter.

Download Data Sheet

Availability: In stock

$2,799.00

Details

Features

  • Small, streamlined shape, rugged, reliable design stands up to field use
  • Easy to read measure/source screen lets you view input and output simultaneously
  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Source mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Support flow meter testing with frequency and CPM functions
  • Perform fast linearity tests with auto- step and auto-ramp features
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms
  • Store frequently used test setups for later use


Specs

  • Measurement Accuracy
    Voltage DC 30.000 V 0.02% + 2 counts (upper display)
    30.000 V 0.02% + 2 counts (lower display)
    100.00 mV 0.02% + 2 counts
    -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
    Current DC 24.000 mA 0.02% + 2 counts
    Resistance 0.0 to 400.0 Ω 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
    401 to 1500 Ω 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
    1500 to 3200 Ω 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
    Frequency 2.0 to 1000.0 CPM 0.05% + 1 count
    1.0 to 1100.0 Hz 0.05% + 1 count
    1.00 to 10.00 kHz 0.05% + 1 count
    Sensitivity 1 V peak-to-peak-minimum
    Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
    Source Accuracy
    Voltage DC 100.00 mV 0.02% + 2 counts
    10.000 V 0.02% + 2 counts
    -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
    Current DC 24.000 mA (source) 0.02% + 2 counts
    24.000 mA (simulate) 0.02% + 2 counts
    Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
    401 to 1500 Ω 0.5 Ω (excitation current 0.05 to 0.8 mA)
    1500 to 3200 Ω 1 Ω (excitation current 0.05 to 0.4 mA)
    Frequency 2.0 to 1000.0 CPM 0.05%
    1.0 to 1100.0 Hz 0.05%
    1.00 to 10.00 kHz 0.25%
    Waveform 5 V p-p squarewave, -0.1 V offset
    RTDs and Thermocouples
    Measure accuracy NI-120 0.2°C
    PT-100 (385) 0.33°C
    PT-100 (393) 0.3°C
    PT-100 (JIS) 0.3°C
    PT-200 (385) 0.2°C
    PT-500 (385) 0.3°C
    PT-1000 (385) 0.2°C
    Resolution 0.1°C
    J 0.7°C
    K 0.8°C
    T 0.8°C
    E 0.7°C
    R 1.8°C
    S 1.5°C
    B 1.4°C
    L 0.7°C
    U 0.75°C
    N 0.9°C
    Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
    XK 0.6°C
    BP 1.2°C
    Source accuracy NI-120 0.2°C
    PT-100 (385) 0.33°C
    PT-100 (393) 0.3°C
    PT-100 (JIS) 0.3°C
    PT-200 (385) 0.2°C
    PT-500 (385) 0.3°C
    PT-1000 (385) 0.2°C
    Resolution 0.1°C
    Accuracy stated for 4-wire measurement.
    J 0.7°C
    K 0.8°C
    T 0.8°C
    E 0.7°C
    R 1.4°C
    S 1.5°C
    B 1.4°C
    L 0.7°C
    U 0.75°C
    N 0.9°C
    Resolution J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
    XK 0.6°C
    BP 1.2°C
    Specifications
    Ramp functions Source functions Voltage, current, resistance, frequency, temperature
    Ramps Slow ramp, Fast ramp, 25% step-ramp
    Loop power function Voltage 24 V
    Accuracy 10%
    Maximum current 22 mA, short circuit protected
    Step functions Source functions Voltage, current, resistance, frequency, temperature
    Steps 25% of range, 100% of range
    Environmental Specifications
    Operating temperature -10°C to +55°C
    Storage temperature -20°C to 71°C
    Operating altitude 3000 m
    Safety Specifications
    Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
    Mechanical and General Specifications
    Size 130 x 236 x 61 mm
    Weight 0.65 kg
    Batteries 4 AA alkaline batteries
    Battery replacement Separate battery compartment, accessable without breaking calibration seal
    Side port connections Pressure module connector, also used for remote real-time programming
    1. Be the first to review this product

    Write Your Own Review

    How do you rate this product? *

      1 star 2 stars 3 stars 4 stars 5 stars
    Quality
    Price
    Value