1-800-921-9494EMAIL US
0item(s)

You have no items in your toolbox.

Product was successfully added to your shopping cart.
Fluke T6-1000 Electrical Tester with FieldSense

Fluke T6-1000 Electrical Tester with FieldSense

$249.99

(In stock)

Fluke T6-1000 Electrical Tester with FieldSense

Quick Overview

Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage. + Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm 2 ), carrying as much as 200 A.

Download Data Sheet | Download Manual

Availability: In stock

$249.99

Details

The T6-1000 with FieldSense technology lets you measure AC voltage and AC current with or without test leads. Its compact design lets you access tight spaces that were previously not possible. With FieldSense selected, slide the open jaw around a cable and measure up to 200 A and 1000 V without breaking the circuit. The backlit display shows both values simultaneously. Plus, with frequency measuring and resistance measurement up to 100 kΩ, the T6 is the perfect front-line tool for your tool bag.
  • Be Safer: Measure voltage to 1000V through the open fork, without test leads
  • Be faster: No need to open covers or remove wire nuts - simultaneously measure voltage and current
  • Be everywhere: Widest open fork in the industry, measure 4/0 wires up to 200A
  • FieldSense Voltage Measurement up to 1000v
  • Ac Input Current: 200A
  • Resistance Range: 100 kohm
  • Frequency Range: 45-66 Hz
  • Each Unit Includes
  • Attached test leads with removable 4 mm probe caps
  • user documentation
Specifications
Calibration 1-year calibration cycle
Dimensions 61.1 mm x 259.3 mm x 43.8 mm
Fork opening 17. 8 m m
Temperature
Operating: -10 °C to +50 °C (14 °F to 122 °F)
Storage: -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating: 2,000 m (6,562 feet)
Storage: 10,000 m (32,808 feet)
Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
RF Field Specification 0.5 % full scale + (specified accuracy) at 3 V / m
Enclosure Rating IP 52 per IEC/EN 60529, no vacuum applied
Temperature coefficient 0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F)
Safety IEC/EN 61010-1, IEC/EN 61010-2-033: Pollution Degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable
  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality