Features
  • Calibrate whole calibration loop
  • Excellent temperature uniformity
  • Wide operating range - ambient to 650°C (1202°F)
  • Ideal for field use
  • Simple to use and outstanding value
  • Temperature Range: 35°C to 650°C
  • Accuracy: ≤0.3°C Throughout entire range
  • Cooling Time: 650°C to 150°C in 60 minutes
  • Heating Time: 30°C to 650°C in 20 minutes
The Isotech Jupiter 650 dry block calibrator offers industry-leading performance in an easy-to-use portable package. With its wide temperature range, the Isotech Jupiter 650 dry block calibrator will reach that important 1200°F mark making it ideal for the calibration of thermocouples as well as platinum resistance thermometers. The Isotech Jupiter 650 dry block calibrator has been designed for fast heating and cooling for convenient field use. For flexibility, surface sensor and infrared thermometer accessories can be added. The Isotech Jupiter 650 dry block calibrator's standard insert can hold up to six thermometers. For larger blocks, see the Gemini and Medusa models. All Isotech calibrators including the Isotech Jupiter 650 dry block calibrator include a customized controller with 5 point linearization allowing for unmatched absolute accuracy and repeatability in a portable dry block. The SITE model of the Isotech Jupiter 650 dry block calibrator has a universal sensor input allowing Platinum Resistance Thermometers, Thermocouples (K, N, R, S, L, B, PL2, T, J & E) along with Linear Process Inputs including 4-20mA current transmitters to be displayed on the built-in indicator. The Isotech Jupiter 650 dry block calibrator's SITE indicator is commonly used to display an external standard thermometer giving greater accuracy by eliminating temperature gradient and loading errors. The indicator also can be programmed with up to five calibration points to provide high accuracy digital probe matching. Cal Notepad software now comes standard with the Isotech Isocal 6 Temperature Calibrator. Cal NotePad Software automatically logs and displays the temperature of an Isotech calibration bath together with the sensor under test. Cal Notepad can be used with baths (or indicators) without PC interfaces by the user typing in values from the keyboard.
Write Your Own Review
You're reviewing:Isotech Jupiter 650 Calibrator
Your Rating